dc.description.abstract |
Hydraulic conductivity is the most variable parameter in geotechnical engineering. Although accurate measurement of hydraulic conductivity of fine-grained soil is not an easy task, it is often required to satisfy the legitimate requirements of various agencies regulating the design, construction, and operation of compacted clay liners. Results are sensitive to the experimental apparatus and testing procedure used for the measurement. As the flow volumes being measured are very small, any minute leakage of permeant during the test will significantly affect the results obtained. The quantification of a significant unexpected loss of permeant through fixed wall permeameters made of Lucite is documented and discussed in this paper. Copyright © 2005 by ASTM International. |
dc.format.extent |
|
dc.format.extent |
Pages: (472-477) |
dc.language |
English |
dc.relation.ispartof |
Publication Name: Geotechnical Testing Journal; Publication Year: 2005; Volume: 28; no. 5; Pages: (472-477); |
dc.relation.ispartofseries |
|
dc.relation.uri |
|
dc.source |
Scopus |
dc.subject.other |
|
dc.title |
Apparatus induced error in hydraulic conductivity measurement using a Lucite® fixed wall permeameter |
dc.type |
Article |
dc.contributor.affiliation |
Yeung, A.T., Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, Hong Kong |
dc.contributor.affiliation |
Sadek, S.M., American University of Beirut, Department of Civil and Environmental Engineering, P.O. Box 11-0236, Riad El Solh, Beirut 1107 2020, Lebanon |
dc.contributor.authorAddress |
Yeung, A.T.; Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, Hong Kong |
dc.contributor.authorCorporate |
University: American University of Beirut; Faculty: Faculty of Engineering and Architecture; Department: Civil and Environmental Engineering; |
dc.contributor.authorDepartment |
Civil and Environmental Engineering |
dc.contributor.authorDivision |
|
dc.contributor.authorEmail |
|
dc.contributor.faculty |
Faculty of Engineering and Architecture |
dc.contributor.authorInitials |
|
dc.contributor.authorOrcidID |
|
dc.contributor.authorReprintAddress |
|
dc.contributor.authorResearcherID |
|
dc.contributor.authorUniversity |
American University of Beirut |
dc.description.cited |
|
dc.description.citedCount |
|
dc.description.citedTotWOSCount |
|
dc.description.citedWOSCount |
|
dc.format.extentCount |
6 |
dc.identifier.articleNo |
|
dc.identifier.coden |
GTJOD |
dc.identifier.pubmedID |
|
dc.identifier.scopusID |
24644438777 |
dc.identifier.url |
|
dc.publisher.address |
|
dc.relation.ispartofConference |
|
dc.relation.ispartofConferenceCode |
|
dc.relation.ispartofConferenceDate |
|
dc.relation.ispartofConferenceHosting |
|
dc.relation.ispartofConferenceLoc |
|
dc.relation.ispartofConferenceSponsor |
|
dc.relation.ispartofConferenceTitle |
|
dc.relation.ispartofFundingAgency |
|
dc.relation.ispartOfISOAbbr |
|
dc.relation.ispartOfIssue |
5 |
dc.relation.ispartOfPart |
|
dc.relation.ispartofPubTitle |
Geotechnical Testing Journal |
dc.relation.ispartofPubTitleAbbr |
Geotech Test J |
dc.relation.ispartOfSpecialIssue |
|
dc.relation.ispartOfSuppl |
|
dc.relation.ispartOfVolume |
28 |
dc.source.ID |
|
dc.type.publication |
Journal |
dc.subject.otherAuthKeyword |
Fixed wall permeameter |
dc.subject.otherAuthKeyword |
Hydraulic conductivity |
dc.subject.otherAuthKeyword |
Lucite |
dc.subject.otherAuthKeyword |
Measurement error |
dc.subject.otherChemCAS |
|
dc.subject.otherIndex |
Building materials |
dc.subject.otherIndex |
Clay |
dc.subject.otherIndex |
Corrosion resistance |
dc.subject.otherIndex |
Electric currents |
dc.subject.otherIndex |
Hydraulic conductivity |
dc.subject.otherIndex |
Soils |
dc.subject.otherIndex |
Fixed wall permeameter |
dc.subject.otherIndex |
Lucite |
dc.subject.otherIndex |
Measurement error |
dc.subject.otherIndex |
Geotechnical engineering |
dc.subject.otherKeywordPlus |
|
dc.subject.otherWOS |
|