Limitations of platform assays to measure serum 25OHD level impact on guidelines and practice decision making
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
W.B. Saunders
Abstract
Context: Liquid Chromatography Mass Spectroscopy (LC-MS/MS) is the preferred method to measure 25 hydroxyvitamin D (25OHD) levels, but laboratories are increasingly adopting automated platform assays. Objective: We assessed the performance of commonly used automated immunoassays, with that of LC-MS/MS, and the National Institute of Standards and Technology (NIST) reference values, to measure 25OHD levels. Methods/Setting: We compared serum 25OHD levels obtained from 219 elderly subjects, enrolled in a vitamin D trial, using the Diasorin Liaison platform assay, and the tandem LC-MS/MS method. We also assessed the performance of the Diasorin and Roche automated assays, expressed as mean % bias from the NIST standards, based on the vitamin D External Quality Assessment Scheme (DEQAS) reports, from 2013 to 2017. Results: Serum 25OHD levels were significantly lower in the Diasorin compared to LC-MS/MS assay at baseline, 18.5 ± 7.8 vs 20.5 ± 7.6 ng/ml (p < 0.001), and all other time points. Diasorin (25OHD) = 0.76 × LC-MS/MS (25OHD) + 4.3, R 2 = 0.596. The absolute bias was independent of 25OHD values, and the pattern unfit for any cross-calibration. The proportion of subjects considered for vitamin D treatment based on pre-set cut-offs differed significantly between the 2 assays. There also was wide variability in the performance of both automated assays, compared to NIST reference values. Conclusion: The performance of most widely used automated assays is sub-optimal. Our findings underscore the pressing need to re-consider current practices with regard to 25OHD measurements, interpretation of results from research studies, meta-analyses, the development of vitamin D guidelines, and their relevance to optimizing health. © 2018 Elsevier Inc.
Description
Keywords
Aged, Automation, Chromatography, high pressure liquid, Clinical decision-making, Female, Guidelines as topic, Humans, Immunoassay, Luminescence, Male, Mass spectrometry, Nutritional status, Overweight, Reference values, Reproducibility of results, Vitamin d, Vitamin d deficiency, 25 hydroxyvitamin d, 25-hydroxyvitamin d, Adult, Article, Clinical decision making, Controlled study, Human, Liquid chromatography-mass spectrometry, Major clinical study, Practice guideline, Priority journal, Reference value, Vitamin blood level, Analogs and derivatives, Blood, High performance liquid chromatography, Obesity, Reproducibility