Indoor Air Quality in Hospitals: PM and Airborne Viruses

dc.contributor.advisorEl Fadel, Mutasem
dc.contributor.authorHanna, Francis
dc.contributor.commembersAlameddine, Ibrahim
dc.contributor.commembersZaraket, Hassan
dc.contributor.departmentDepartment of Civil and Environmental Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture
dc.contributor.institutionAmerican University of Beirut
dc.date2020
dc.date.accessioned2020-09-23T11:19:22Z
dc.date.available2020-09-23T11:19:22Z
dc.date.issued2020
dc.description.abstractIn this study, we characterize particulate matter concentrations and airborne viruses at a health care facility and explore correlations with indoor parameters such as the air exchange rate, relative humidity and temperature. We also examine the transmission, decay, and suspension of virus shedding by patients. For this purpose, PM2.5, PM10, and airborne viruses (influenza A, influenza B, respiratory syncytial virus (RSV)) were monitored in patient rooms with confirmed infections. The indoor measurements showed that patients were exposed to elevated PM2.5 levels, ranging between 7 and 53 µg/m3 with a mean of 24.5 µg/m3, and to PM10 concentrations that reached 89 µg/m3. Overall, 91% of the monitored patient rooms exceeded the PM2.5 daily exposure level of 10 mg/m3, while 70% of the rooms exceeded the PM10 daily exposure level of 20 mg/m3. Influenza A was detected in 42% of the monitored rooms, with concentrations ranging between 222 and 5,760 copies/m3, with a mean of 820 copies/m3. The results showed that while viral concentrations (RNA copies/m3) tended to decrease significantly with distance away from the patient, traces were still detectable at 1 m and even at 1.5 m. Statistical and numerical analyses clearly showed that the viral removal efficiency was affected by changes in the relative humidity more than changes in room temperature. Moreover, the results from a calibrated Gaussian puff model showed that dispersion was the dominant pathways for viral removal. Based on the results of this study, a set of mitigation measures are proposed within a management framework to reduce exposure of staff, visitors and patients to particulate matter and airborne viruses in hospitals.
dc.identifier.urihttp://hdl.handle.net/10938/21980
dc.language.isoen
dc.subjectIndoor Air Quality
dc.subjectHealthcare Facilities
dc.subjectPM
dc.subjectViruses
dc.subjectInfluenza A
dc.subjectNumerical Modeling
dc.titleIndoor Air Quality in Hospitals: PM and Airborne Viruses
dc.typeThesis

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
HannaFrancis_2020.pdf
Size:
774.36 KB
Format:
Adobe Portable Document Format
Description:
Masters Thesis - Francis Hanna

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.65 KB
Format:
Item-specific license agreed upon to submission
Description: