Use of Contrast-Enhanced Ultrasound for Confirmation of Central Venous Catheter Placement: Systematic Review and Meta-analysis: Systematic
| dc.contributor.author | Bou Chebl, Ralph | |
| dc.contributor.author | Kiblawi, Shafeek | |
| dc.contributor.author | El Khuri, Christopher | |
| dc.contributor.author | El Hajj, Nadine | |
| dc.contributor.author | Bachir, Rana H. | |
| dc.contributor.author | Aoun, Roni | |
| dc.contributor.author | Abou Dagher, Gilbert | |
| dc.contributor.department | Emergency Medicine | |
| dc.contributor.faculty | Faculty of Medicine (FM) | |
| dc.contributor.institution | American University of Beirut | |
| dc.date.accessioned | 2025-01-24T11:41:28Z | |
| dc.date.available | 2025-01-24T11:41:28Z | |
| dc.date.issued | 2017 | |
| dc.description.abstract | Objectives: The purpose of this meta-analysis was to determine the sensitivity, specificity, and positive and negative predictive values of contrast-enhanced ultrasound (US) for confirming the tip location and placement of central venous catheters in adult patients. Methods: A systematic review was performed using electronic databases, including MEDLINE, ClinicalTrials.gov, Cochrane, Embase, PubMed, and Scopus. Inclusion criteria were studies conducted on adult patients receiving an internal jugular or a subclavian central venous catheter in the emergency department or intensive care unit. Furthermore, the catheter tip location had to be checked with the use of the agitated saline contrast-enhanced US technique. Results: A total of 2245 articles were screened by title and abstract. Seventeen articles were retrieved and assessed for the predefined inclusion criteria. Four articles and 1 abstract were used in the final analysis. Contrast-enhanced US showed pooled sensitivity of 72% (95% confidence interval, 44%-91%), pooled specificity of 100% (95% confidence interval, 99%-100%), a positive predictive value of 92.1%, and a negative predictive value of 98.5% compared with chest radiography for confirming the placement of central venous catheters. Conclusions: In the setting of central venous catheter placement, postprocedural contrast-enhanced US imaging is a safe, efficient, and highly specific confirmatory test for the catheter tip location compared with chest radiography. © 2017 by the American Institute of Ultrasound in Medicine. | |
| dc.identifier.doi | https://doi.org/10.1002/jum.14296 | |
| dc.identifier.eid | 2-s2.0-85040818780 | |
| dc.identifier.pmid | 28660688 | |
| dc.identifier.uri | http://hdl.handle.net/10938/29752 | |
| dc.language.iso | en | |
| dc.publisher | John Wiley and Sons Ltd. | |
| dc.relation.ispartof | Journal of Ultrasound in Medicine | |
| dc.source | Scopus | |
| dc.subject | Catheter | |
| dc.subject | Critical care | |
| dc.subject | Emergency medicine | |
| dc.subject | Position | |
| dc.subject | Radiography | |
| dc.subject | Ultrasound | |
| dc.subject | Catheterization, central venous | |
| dc.subject | Central venous catheters | |
| dc.subject | Contrast media | |
| dc.subject | Humans | |
| dc.subject | Image enhancement | |
| dc.subject | Jugular veins | |
| dc.subject | Sensitivity and specificity | |
| dc.subject | Subclavian vein | |
| dc.subject | Ultrasonography, interventional | |
| dc.subject | Intensive care units | |
| dc.subject | Location | |
| dc.subject | Medicine | |
| dc.subject | Ultrasonic applications | |
| dc.subject | Ultrasonics | |
| dc.subject | Contrast medium | |
| dc.subject | Contrast enhanced ultrasound | |
| dc.subject | Electronic database | |
| dc.subject | Emergency departments | |
| dc.subject | Negative predictive value | |
| dc.subject | Positive predictive values | |
| dc.subject | Central venous catheter | |
| dc.subject | Central venous catheterization | |
| dc.subject | Devices | |
| dc.subject | Diagnostic imaging | |
| dc.subject | Human | |
| dc.subject | Interventional ultrasonography | |
| dc.subject | Jugular vein | |
| dc.subject | Meta analysis | |
| dc.subject | Procedures | |
| dc.subject | Catheters | |
| dc.title | Use of Contrast-Enhanced Ultrasound for Confirmation of Central Venous Catheter Placement: Systematic Review and Meta-analysis: Systematic | |
| dc.type | Review |