3D/4D sonography - any safety problem

dc.contributor.authorPooh, Ritsuko Kimata
dc.contributor.authorMaeda, Kazuo
dc.contributor.authorKurjak, Asim
dc.contributor.authorŞen, Cihat
dc.contributor.authorEbrashy, Alaa
dc.contributor.authorAdra, Abdallah M.
dc.contributor.authorAliyu, Labaran Dayyabu
dc.contributor.authorWataganara, Tuangsit
dc.contributor.authorMoreira de Sa, Renato Augusto
dc.contributor.authorStanojević, Milan
dc.contributor.departmentObstetrics and Gynecology
dc.contributor.departmentMaternal Fetal Medicine
dc.contributor.facultyFaculty of Medicine (FM)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T12:07:59Z
dc.date.available2025-01-24T12:07:59Z
dc.date.issued2016
dc.description.abstractGray-scale image data are processed in 3D ultrasound by repeated scans of multiple planes within a few seconds to achieve one surface rendering image and three perpendicular plane images. The 4D image is achieved by repeating 3D images in short intervals, i.e. 3D and 4D ultrasound are based on simple B-mode images. During 3D/4D acquisition, a fetus in utero is exposed by ultrasound beam for only a few seconds, and it is as short as real-time B-mode scanning. Therefore, simple 3D imaging is as safe as a simple B-mode scan. The 4D ultrasound is also as safe as a simple B-mode scan, but the ultrasound exposure should be shorter than 30 min. The thermal index (TI) and mechanical index (MI) should both be lower than 1.0, and the ultrasound study is regulated by the Doppler ultrasound if it is combined with simple 3D or 4D ultrasound. Recently, some articles have reported the functional changes of animal fetal brain neuronal cells and liver cell apoptosis with Doppler ultrasound. We discuss cell apoptosis by ultrasound in this report. Diagnostic ultrasound safety is achieved by controlling the output pulse and continuous ultrasound waves using thermal and mechanical indices, which should be <1.0 in abdominal and transvaginal scan, pulsed Doppler, as well as 3D and 4D ultrasound. The lowest spatial peak temporal average (SPTA) intensity of the ultrasound to suppress cultured cell growth is 240 mW/cm2, below which no ultrasound effect has been reported. An ultrasound user must be trained to recognize the ultrasound bioeffects; thermal and mechanical indices, and how to reduce these when they are higher than 1.0 on the monitor display; and guide the proper use of the ultrasound under the ALARA principle, because the user is responsible for ensuring ultrasound safety.
dc.identifier.doihttps://doi.org/10.1515/jpm-2015-0225
dc.identifier.eid2-s2.0-84962604812
dc.identifier.pmid26376219
dc.identifier.urihttp://hdl.handle.net/10938/31666
dc.language.isoen
dc.publisherWalter de Gruyter GmbH
dc.relation.ispartofJournal of Perinatal Medicine
dc.sourceMedline
dc.subjectAnimals
dc.subjectFemale
dc.subjectFetus/diagnostic imaging
dc.subjectHumans
dc.subjectImaging, three-dimensional/adverse effects/methods
dc.subjectInfant, newborn
dc.subjectPregnancy
dc.subjectSafety
dc.subjectUltrasonography, prenatal/adverse effects/methods
dc.title3D/4D sonography - any safety problem
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2016-9650.pdf
Size:
388.89 KB
Format:
Adobe Portable Document Format