Extensive circumferential partial-thickness sclerectomy in eyes with extreme nanophthalmos and spontaneous uveal effusion

dc.contributor.authorMansour, Ahmad Mohammed Farid Mahmoud
dc.contributor.authorStewart, Michael Wesley
dc.contributor.authorShields, Carol Lally
dc.contributor.authorHamam, Rola N.
dc.contributor.authorAbdul Fattah, Maamoun
dc.contributor.authorSheheitli, Huda A.
dc.contributor.authorMehanna, Carl Joe
dc.contributor.authorYassine, Salma W.
dc.contributor.authorChahine, Hasan
dc.contributor.authorKeaik, Mona
dc.contributor.authorMaalouf, Fadi C.
dc.contributor.authorJaroudi, Mahmoud O.
dc.contributor.departmentOphthalmology
dc.contributor.facultyFaculty of Medicine (FM)
dc.contributor.facultyFaculty of Health Sciences (FHS)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T12:08:40Z
dc.date.available2025-01-24T12:08:40Z
dc.date.issued2019
dc.description.abstractAim To describe an extensive scleral excision technique to treat uveal effusion in nanophthalmic eyes. Methods This prospective, interventional series of eight eyes of five consecutive patients with nanophthalmos underwent scleral window surgeries. Ninety per cent of the scleral thickness, extending from immediately behind the extraocular muscle insertions to the vortex veins for 3 and 1/4 quadrants, was removed. The main outcome measure was resolution of the uveal effusions. Results Eight eyes of five patients (one female and four male) with a mean age of 46 years were studied. The mean (range) axial length was 16.1 mm (14.6-17.6 mm), and the mean refractive error was +13.6 dioptres (+10.75 to +16.00 dioptres). Following scleral excision surgery, all uveal effusions resolved within an average (±SD) of 13.9 (±8.7) days. The uveal effusion recurred in only one eye that had a vasoproliferative retinal tumour. The mean best corrected visual acuity improved from 0.69 logarithm of the minimum angle of resolution (logMAR) (Snellen equivalent: 20/97) at baseline to 0.51 logMAR (Snellen equivalent: 20/64; Wilcoxon paired t-test: p=0.016) after a mean follow-up of 35.6 months. Conclusion The circumferential scleral window technique produces rapid resolution of uveal effusion in nanophthalmic eyes. No adverse effects were noted after surgery and the clinical effect was durable through 1 year. Trial registration number NCT03748732. © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.
dc.identifier.doihttps://doi.org/10.1136/bjophthalmol-2018-313702
dc.identifier.eid2-s2.0-85063073288
dc.identifier.pmid30877130
dc.identifier.urihttp://hdl.handle.net/10938/31877
dc.language.isoen
dc.publisherBMJ Publishing Group
dc.relation.ispartofBritish Journal of Ophthalmology
dc.sourceScopus
dc.subjectMacula
dc.subjectNanophthalmos
dc.subjectRetina
dc.subjectSclera and episclera
dc.subjectUveal effusion
dc.subjectAdult
dc.subjectAxial length, eye
dc.subjectFemale
dc.subjectFluorescein angiography
dc.subjectFollow-up studies
dc.subjectHumans
dc.subjectMale
dc.subjectMicrophthalmos
dc.subjectMiddle aged
dc.subjectProspective studies
dc.subjectSclera
dc.subjectSclerostomy
dc.subjectTomography, optical coherence
dc.subjectUveal effusion syndrome
dc.subjectVisual acuity
dc.subjectArticle
dc.subjectBest corrected visual acuity
dc.subjectClinical article
dc.subjectFollow up
dc.subjectGroups by age
dc.subjectHuman
dc.subjectMicrophthalmia
dc.subjectOutcome assessment
dc.subjectPriority journal
dc.subjectProspective study
dc.subjectRefraction error
dc.subjectRetina tumor
dc.subjectSclerectomy
dc.subjectUvea disease
dc.subjectComplication
dc.subjectEtiology
dc.subjectEye axis length
dc.subjectFluorescence angiography
dc.subjectOptical coherence tomography
dc.subjectPathology
dc.subjectPathophysiology
dc.subjectPhysiology
dc.subjectProcedures
dc.subjectSurgery
dc.titleExtensive circumferential partial-thickness sclerectomy in eyes with extreme nanophthalmos and spontaneous uveal effusion
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2019-7227.pdf
Size:
1.37 MB
Format:
Adobe Portable Document Format

Collections