Cardiac implantable electronic device infections

dc.contributor.authorRefaat, Marwan M.
dc.contributor.authorZakka, Patrick K.
dc.contributor.authorKhoury, Maurice Y.
dc.contributor.authorChami, Hassan A.
dc.contributor.authorMansour, Shareef
dc.contributor.authorHarbieh, Bernard
dc.contributor.authorAbi-Saleh, Bernard S.
dc.contributor.authorBizri, Abdul Rahman N.
dc.contributor.departmentInternal Medicine
dc.contributor.facultyFaculty of Medicine (FM)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:55:43Z
dc.date.available2025-01-24T11:55:43Z
dc.date.issued2019
dc.description.abstractWith increasing rates of device implantation, there is an increased recognition of device infection. We conducted a retrospective observational study in a tertiary care center in Lebanon, with data collected from medical records of patients presenting with cardiac implantable electronic device (CIED) infection from 2000 to 2017 with the purpose of identifying etiologies, risk factors and other parameters, and comparing them to available data from the rest of the world. We identified a total of 22 CIED infections. The most common microbial etiologies, including involvement in polymicrobial infection, were coagulase-negative staphylococci (45.5%) and Staphylococcus aureus (22.7%). Rare cases of Brucella melitensis, Sphingomonas paucimobilis, and Kytococcus schroeteri device infection were seen. Heart failure was seen in 77.3% of patients, hypertension in 68.2%, and chronic kidney disease in 50%. Skin changes were the most common presenting symptoms (86.4%). Antibiotics were given to all patients and all had their devices removed, with 36.4% undergoing new device implantation. This is the first study of CIED infections in Lebanon and the Middle East. Local epidemiology and occupational exposure must be considered while contemplating the microbial etiology of infection. Close monitoring after device implantation is important in preventing device infection that carries high risk of morbidity and mortality. Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc.
dc.identifier.doihttps://doi.org/10.1097/MD.0000000000014906
dc.identifier.eid2-s2.0-85065087847
dc.identifier.pmid31008922
dc.identifier.urihttp://hdl.handle.net/10938/31216
dc.language.isoen
dc.publisherLippincott Williams and Wilkins
dc.relation.ispartofMedicine (United States)
dc.sourceScopus
dc.subjectCardiac implantable electronic device
dc.subjectCardiac implantable electronic device infection
dc.subjectImplantable cardioverter defibrillator
dc.subjectPacemaker
dc.subjectAdolescent
dc.subjectAdult
dc.subjectAged
dc.subjectAged, 80 and over
dc.subjectChild
dc.subjectChild, preschool
dc.subjectDefibrillators, implantable
dc.subjectFemale
dc.subjectHumans
dc.subjectInfant
dc.subjectLebanon
dc.subjectMale
dc.subjectMedical records
dc.subjectMiddle aged
dc.subjectPacemaker, artificial
dc.subjectProsthesis-related infections
dc.subjectRetrospective studies
dc.subjectRisk factors
dc.subjectStaphylococcal infections
dc.subjectStaphylococcus aureus
dc.subjectYoung adult
dc.subjectArtificial heart pacemaker
dc.subjectHuman
dc.subjectInfection
dc.subjectIsolation and purification
dc.subjectMedical record
dc.subjectMicrobiology
dc.subjectPreschool child
dc.subjectRetrospective study
dc.subjectRisk factor
dc.subjectStaphylococcus infection
dc.subjectVery elderly
dc.titleCardiac implantable electronic device infections
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2019-7579.pdf
Size:
731.13 KB
Format:
Adobe Portable Document Format