AN ELECTROMAGNETIC BIOMEDICAL 2.4 GHZ, WEARABLE, NON-INVASIVE TRANSCEIVER FOR CONTINUOUS BLOOD PRESSURE MONITORING

dc.contributor.AUBidnumber201624248
dc.contributor.advisorKabalan, Karim
dc.contributor.authorElabbasi, Mona
dc.contributor.commembersMadi, Mervat
dc.contributor.commembersChehab, Ali
dc.contributor.commembersHassan, Artail
dc.contributor.commembersNassir Hussni, Sabah
dc.contributor.commembersAbou Chahine, Sobhi
dc.contributor.commembersEl Misilmani, Hilal
dc.contributor.degreePhD
dc.contributor.departmentDepartment of Electrical and Computer Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2022-07-18T05:01:25Z
dc.date.available2022-07-18T05:01:25Z
dc.date.submitted7/16/2022
dc.description.abstractPainless, cuffless and continuous blood pressure monitoring sensors provide a more dynamic measure of blood pressure for critical diagnosis or continuous monitoring of hypertensive patients compared to current cuff-based options. To this end, a novel flexible and wearable microstrip patch antenna topology is proposed to measure dynamic blood pressure (BP). The methodology was implemented on a simulated five-layer human tissue arm model created and designed in High-Frequency Simulation Software “HFSS”. The electrical properties of the five-layer human tissue were set at the frequency range (2–3) GHz to comply with clinical/engineering standards. The fabricated patch incorporated on a 0.4 mm epoxy substrate achieved consistency between the simulated and measured reflection coefficient results at flat and bent conditions over the frequency range of 2.3–2.6 GHz. Simulations for a 10 g average specific absorption rate (SAR) based on IEEE-Standard for a human arm at different input powers were also carried out. The safest input power was 50 mW with an acceptable SAR value of 3.89 W/Kg < 4W/Kg. This study also explored a novel method to obtain the pulse transit time (PTT) as an option to measure BP. Pulse transmit time is based on obtaining the time difference between the transmission coefficient scattering waveforms measured between the two pairs of metallic sensors underlying the assumption that brachial arterial geometries are dynamic. Consequently, the proposed model is validated by comparing it to the standard nonlinear Moens and Korteweg model over different artery thickness-radius ratios, showing excellent correlation between 0.76 ± 0.03 and 0.81 ± 0.03 with the systolic and diastolic BP results. The absolute risk of arterial blood pressure increased with the increase in brachial artery thickness-radius ratio. The results of both methods successfully demonstrate how the radius estimates, PTT and pulse wave velocity (PWV), along with electromagnetic (EM) antenna transmission propagation characteristics, can be used to estimate continuous BP non-invasively.
dc.identifier.urihttp://hdl.handle.net/10938/23492
dc.language.isoen
dc.subjectmicrostrip patch antenna; transmission coefficient scattering parameter; specific absorption rate; Moens-Korteweg equation; brachial artery radius-to-tissue thickness ratio; blood pressure
dc.titleAN ELECTROMAGNETIC BIOMEDICAL 2.4 GHZ, WEARABLE, NON-INVASIVE TRANSCEIVER FOR CONTINUOUS BLOOD PRESSURE MONITORING
dc.typeDissertation

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ElAbbasiMona-2022.pdf
Size:
1.68 MB
Format:
Adobe Portable Document Format
Description:
Disseration 2022

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.65 KB
Format:
Item-specific license agreed upon to submission
Description: