Is Ductography Still Warranted in the 21st century?

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Blackwell Publishing Inc.

Abstract

Objective: To determine the utility of ductography in conjunction with mammography and ultrasound in patients with pathologic nipple discharge, and the incremental role of MRI after triple-modality evaluation. Materials and Methods: We retrospectively reviewed the medical records of patients who had presented with pathologic nipple discharge and had undergone mammography and/or ultrasound and ductography between January 1, 2005, and October 31, 2010. We tested the diagnostic sensitivity, specificity and accuracy of combined triple-modality evaluation as well as of MRI performed in addition to these imaging techniques. We used the gold standard of image-guided biopsies, surgical excision, or long-term clinical and imaging follow-up. Results: Among 94 study patients, benign papillomas were identified in 42 (44.7%), abscess in one (1%), duct ectasia in four (4.3%), and malignancy (invasive ductal carcinoma or ductal carcinoma in situ) or high-risk lesion (atypical ductal hyperplasia) in 10 (10.6%). Forty-six patients (49%) underwent surgical excision; 89.1% of which had presurgical planning with ductography. In 35 (37.2%) with negative imaging, resolution of nipple discharge was confirmed on median clinical and imaging follow-up of 36 months. Two patients with negative imaging were lost to follow-up. Sensitivity, specificity, PPV, and NPV for accurately demonstrating the etiology of pathologic nipple discharge were 13%, 97%, 89%, and 37% respectively for mammography; 73%, 97%, 98%, and 64% respectively for ultrasound; 76%, 72%, 84%, and 61% respectively for ductography; 86%, 70%, 85%, and 72% respectively for combined ultrasound and ductography; and 75%, 100%, 100% and 67% respectively for DCE-MRI. Conclusion: The combination of mammography, ultrasound and ductography is highly accurate for identifying the etiology of pathologic nipple discharge. DCE-MRI can be used as an alternate to ductography if necessary. © 2019 Wiley Periodicals, Inc.

Description

Keywords

Breast, Dce-mri, Ductography, Pathologic nipple discharge, Ultrasound, Adult, Aged, Aged, 80 and over, Breast diseases, Breast neoplasms, Contrast media, Female, Humans, Image-guided biopsy, Magnetic resonance imaging, Mammography, Middle aged, Nipple discharge, Retrospective studies, Sensitivity and specificity, Ultrasonography, mammary, Young adult, Contrast medium, Article, Atypical ductal hyperplasia, Breast abscess, Breast carcinoma, Breast discharge, Breast duct ectasia, Breast papilloma, Contrast radiography, Diagnostic accuracy, Dynamic contrast-enhanced magnetic resonance imaging, Echography, Excision, Follow up, Histopathology, Human, Human tissue, Image guided biopsy, Intraductal carcinoma, Major clinical study, Medical record review, Breast disease, Breast tumor, Diagnostic imaging, Echomammography, Nuclear magnetic resonance imaging, Pathology, Procedures, Retrospective study, Very elderly

Citation

Endorsement

Review

Supplemented By

Referenced By