Interior RC wide beam-narrow column joints: Potential for improving seismic resistance

dc.contributor.authorElsouri, Amer M.
dc.contributor.authorHarajlí, Mohamed H.
dc.contributor.departmentDepartment of Civil and Environmental Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:26:50Z
dc.date.available2025-01-24T11:26:50Z
dc.date.issued2015
dc.description.abstractDesign codes (ACI 318-08, 2008; ACI Committee 352-02, 2010) place restrictions on the use of reinforced concrete (RC) wide-beam framing systems in regions of seismic hazard because there are little or insufficient information about their behavior under the effects of earthquake loads. The current study constitutes the second part of an experimental investigation carried out for (i) evaluating the seismic response of RC wide and shallow beam-narrow column joints when designed and detailed under gravity load; and (ii) for exploring the potential of improving the seismic performance of the same joints without introducing significant changes in the design and construction practices. The first part of the investigation concentrated on exterior joints, the results of which were reported elsewhere (Elsouri, 2013). This study concentrates on interior joints, in which four full-scale beam-column sub-assemblages were tested under quasi-static cyclic loading. Two of the joints, referred to as as-built, were designed and detailed for gravity load in accordance with local design and construction practices. The other two joints, referred to as earthquake-resistant, were also designed assuming gravity load but their reinforcement detailing were improved to satisfy part of the ACI 318-08 requirements and ACI-ASCE 352-02 recommendations for seismic-resistant structures. The as-built joints experienced shear failure within the joint core at early lateral drift. With a slight improvement of the reinforcement detailing, despite violating the limits of joint dimensions and some detailing requirements of ACI 318-08, the earthquake-resistant joints acquired considerably improved seismic performance by preventing or delaying joint shear failure; and by developing higher lateral load, deformation, and energy dissipation capacities when compared with the as-built joints. © 2015 Elsevier Ltd.
dc.identifier.doihttps://doi.org/10.1016/j.engstruct.2015.04.020
dc.identifier.eid2-s2.0-84929071344
dc.identifier.urihttp://hdl.handle.net/10938/26685
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEngineering Structures
dc.sourceScopus
dc.subjectConcrete
dc.subjectConnection
dc.subjectCyclic
dc.subjectEarthquake
dc.subjectJoint
dc.subjectReinforced
dc.subjectSeismic
dc.subjectColumns (structural)
dc.subjectConcretes
dc.subjectEarthquake resistance
dc.subjectEnergy dissipation
dc.subjectJoints (structural components)
dc.subjectReinforced concrete
dc.subjectSeismic design
dc.subjectSeismic response
dc.subjectSeismic waves
dc.subjectSeismology
dc.subjectStructures (built objects)
dc.subjectDesign and construction practice
dc.subjectEnergy dissipation capacities
dc.subjectQuasi-static cyclic loadings
dc.subjectSeismic resistant structures
dc.subjectColumn
dc.subjectCyclic loading
dc.subjectEarthquake engineering
dc.subjectFailure analysis
dc.subjectGravity field
dc.subjectSeismic hazard
dc.subjectStructural response
dc.subjectEarthquakes
dc.titleInterior RC wide beam-narrow column joints: Potential for improving seismic resistance
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2015-9915.pdf
Size:
3.46 MB
Format:
Adobe Portable Document Format