Direct dripping: A high-temperature, high- formaldehyde emission electronic cigarette use method
Loading...
Files
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Oxford University Press
Abstract
Introduction: Electronic cigarettes (ECIGs) electrically heat and vaporize a liquid solution to produce an inhalable nicotine-containing aerosol. Normally the electrical heater is fed the liquid via an automatic wick system. Some ECIG users, however, elect to directly drip liquid onto an exposed heater coil, reportedly for greater vapor production and throat hit. Use of such direct drip atomizers (DDAs) may involve greater exposure to non-nicotine toxicants due to the potentially higher temperatures reached by the coil. In this study we examined nicotine and volatile aldehyde (VA) emissions from one type of DDA under various use scenarios, and measured heater temperature. Methods: Aerosols were machine-generated from an NHALER 510 Atomizer powered by an eGo-T battery (Joyetech), using a common PG-based liquid and a fixed puffing regimen. Inter-drip interval, the number of puffs drawn between replenishing the liquid on the coil, was varied from 2-4 puffs/drip. Total particulate matter, nicotine, and VA yields were quantified. Heater temperature was monitored using an infrared camera. Results: Depending on the condition, VA emissions, including formaldehyde, greatly exceeded values previously reported for conventional ECIGs and combustible cigarettes, both per puff and per unit of nicotine yield. Increasing the inter-drip interval resulted in greater VA emissions, and lower total particulate matter and nicotine yields. Maximum heater coil temperature ranged from 130°C to more than 350°C. Conclusions: Due to the higher temperatures attained, DDAs are inherently likely to produce high toxicant emissions. The diversity of ECIG use methods, including potential off-label methods, should be considered as ECIG regulatory efforts proceed. © The Author 2015.
Description
Keywords
Aerosols, Drug delivery systems, Electronic cigarettes, Formaldehyde, Hazardous substances, Hot temperature, Nebulizers and vaporizers, Nicotine, Particulate matter, Smoking, Temperature, Aldehyde, Propylene glycol, Volatile agent, Aerosol, Dangerous goods, Article, Camera, Chemical parameters, Direct drip atomizer, Direct dripping, Electric battery, Electronic cigarette, General device, High temperature, Infrared camera, Inter drip interval, Nicotine yield, Priority journal, Quantitative analysis, Temperature measurement, Administration and dosage, Adverse effects, Drug delivery system, Heat, Nebulizer, Procedures