New objective lens density quantification method using swept-source optical coherence tomography technology: Comparison with existing methods

dc.contributor.authorPanthier, Christophe
dc.contributor.authorBurgos, Justine
dc.contributor.authorRouger, Heĺène
dc.contributor.authorSaad, Alain
dc.contributor.authorGatinel, Damien
dc.contributor.departmentOphthalmology
dc.contributor.facultyFaculty of Medicine (FM)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T12:08:34Z
dc.date.available2025-01-24T12:08:34Z
dc.date.issued2017
dc.description.abstractPurpose To assess a new objective cataract grading method based on lens densitometry on swept-source optical coherence tomography (SS-OCT) scans provided by the IOLMaster 700. Settings Rothschild Foundation, Paris, France. Design Prospective case series. Methods All patients consulting for cataract evaluation who provided their consent to participate in the study were included. A history of eye surgery, corneal or retinal disorders, and ocular dryness were exclusion criteria. The average lens densitometry was measured with SS-OCT scans using ImageJ software. The ocular scatter index (OSI) measured with a double-pass aberrometer (Optical Quality Analysis System), the Pentacam nucleus staging (hereafter referred to as nuclear staging) score, and mean nuclear staging were also measured and compared with the mean lens densitometry. Results One hundred ten eyes (51 with cataract and 59 controls) were included. The average lens densitometry measurements were repeatable (P =.99, analysis of variance). The repeatability limit was 2.50 pixel units. The average lens density was correlated with the OSI (r2 = 0.52, P <.01), nuclear staging score (r2 = 0.75, P <.01), and mean nuclear staging (r2 = 0.41, P <.01). An average lens density greater than 82.9 pixel units was the cutoff threshold for cataract, with a sensitivity of 73.9% and a specificity of 91.2%. Conclusions The average lens density measured by SS-OCT was a repeatable and reliable objective cataract grading method. It was correlated with OSI measurement. If the average lens density was greater than 82.9 pixel units and the patient reported visual impairment, cataract surgery might be discussed. © 2017 ASCRS and ESCRS
dc.identifier.doihttps://doi.org/10.1016/j.jcrs.2017.09.028
dc.identifier.eid2-s2.0-85040521240
dc.identifier.pmid29335103
dc.identifier.urihttp://hdl.handle.net/10938/31844
dc.language.isoen
dc.publisherElsevier Inc.
dc.relation.ispartofJournal of Cataract and Refractive Surgery
dc.sourceScopus
dc.subjectCataract
dc.subjectCornea
dc.subjectDensitometry
dc.subjectHumans
dc.subjectLens, crystalline
dc.subjectProspective studies
dc.subjectTomography, optical coherence
dc.subjectAdult
dc.subjectAged
dc.subjectArticle
dc.subjectAstigmatism
dc.subjectControlled study
dc.subjectCross-sectional study
dc.subjectDry eye
dc.subjectFemale
dc.subjectFrance
dc.subjectHuman
dc.subjectLens
dc.subjectMajor clinical study
dc.subjectMale
dc.subjectOptical coherence tomography
dc.subjectPriority journal
dc.subjectProspective study
dc.subjectRetina disease
dc.subjectSlit lamp microscopy
dc.subjectSubcapsular cataract
dc.titleNew objective lens density quantification method using swept-source optical coherence tomography technology: Comparison with existing methods
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2017-8594.pdf
Size:
1.08 MB
Format:
Adobe Portable Document Format