Seismic performance enhancement of steel bolted moment connections.

dc.contributor.authorEl Kalash, Sana Najib
dc.contributor.departmentDepartment of Civil and Environmental Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture
dc.contributor.institutionAmerican University of Beirut
dc.date2019
dc.date.accessioned2020-03-27T21:10:11Z
dc.date.available2020-03-27T21:10:11Z
dc.date.issued2019
dc.date.submitted2019
dc.descriptionDissertation. Ph.D. American University of Beirut. Department of Civil and Environmental Engineering, 2019. ED:122.
dc.descriptionChair of Committee : Dr. Salah Sadek, Professor, Civil and Environmental Engineering ; Advisor : Dr. Elie Hantouche, Assistant Professor, Civil and Environmental Engineering ; Members of Committee : Dr. George Saad, Associate Professor, Civil and Environmental Engineering ; Dr. Camille Issa, Professor, Civil and Environmental Engineering, Lebanese American University ; Dr. Antoine Gergess, Professor, Civil and Environmental Engineering, University of Balamand.
dc.descriptionIncludes bibliographical references (leaves 138-146)
dc.description.abstractThe damage of steel structures caused by recent earthquakes motivated the structural engineering profession to change the prescriptive design guidelines to accommodate for the performance-based seismic design approach. One of its characteristics is that steel structures are expected to go from the linear response to the non-linear response before failure. Thus, the pre-yielding as well as the post-yielding behavior of steel connections is of interest to the structural engineering community. The goal of this research is to investigate innovative techniques to enhance the seismic performance and to lower the fabrication cost of eight-bolt double Tee and extended endplate connections through experimental work and analytical modeling. Despite all the experimental tests and the analytical models conducted on double Tees and extended endplates, very few investigated the influence of the column flange size (thin, medium, and thick), bolt arrangement (circular and rectangular), and omission of continuity plates and stiffeners on the seismic performance. Most importantly, the prying phenomenon caused by the significant bending of the connection (primary prying for the circular bolt configuration) and the column flange (secondary prying) in bolted connections was not experimentally investigated in the literature and not yet included in the current prequalified connections for steel moment frames for seismic applications - ANSI-AISC 358-16. Those prying induced forces in the tension bolts might cause unexpected failure of the connection leading to collapse of moment resisting frames and thus need to be accounted for in the design process. To address the abovementioned shortcomings, first, seven specimens are conducted on double Tee connections subjected to monotonic and cyclic loading. The results of these tests are used to develop stiffness and strength models that predict the behavioral characteristics of the column flange-connection system. This aims at including the secondary prying strength check and associated colu
dc.format.extent1 online resource (xvii, 172 leaves) : illustrations (some color)
dc.identifier.otherb25417277
dc.identifier.urihttp://hdl.handle.net/10938/21621
dc.language.isoen
dc.subject.classificationED:000122
dc.subject.lcshFinite element method.
dc.subject.lcshSteel, Structural.
dc.subject.lcshEarthquake zones.
dc.subject.lcshBuilding, Iron and steel.
dc.subject.lcshSteel I-beams.
dc.subject.lcshSteel framing (Building)
dc.subject.lcshFracture mechanics.
dc.titleSeismic performance enhancement of steel bolted moment connections.
dc.typeDissertation

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ed-122.pdf
Size:
5.53 MB
Format:
Adobe Portable Document Format