Detection of influenza virus in air samples of patient rooms

dc.contributor.authorChamseddine, Ashraf
dc.contributor.authorSoudani, Nadia Y.
dc.contributor.authorKanafani, Zeina A.
dc.contributor.authorAlameddine, Ibrahim M.
dc.contributor.authorDbaibo, Ghassan S.
dc.contributor.authorZaraket, Hassan
dc.contributor.authorEl-Fadel, Mutasem E.
dc.contributor.departmentDepartment of Civil and Environmental Engineering
dc.contributor.departmentExperimental Pathology, Microbiology, and Immunology
dc.contributor.departmentInternal Medicine
dc.contributor.departmentPediatrics and Adolescent Medicine
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.facultyFaculty of Medicine (FM)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:27:58Z
dc.date.available2025-01-24T11:27:58Z
dc.date.issued2021
dc.description.abstractBackground: Understanding the transmission and dispersal of influenza virus and respiratory syncytial virus (RSV) via aerosols is essential for the development of preventative measures in hospital environments and healthcare facilities. Methods: During the 2017–2018 influenza season, patients with confirmed influenza or RSV infections were enrolled. Room air samples were collected close (0.30 m) to and distant (2.20 m) from patients' heads. Real-time polymerase chain reaction was used to detect and quantify viral particles in the air samples. The plaque assay was used to determine the infectiousness of the detected viruses. Findings: Fifty-one air samples were collected from the rooms of 29 patients with laboratory-confirmed influenza; 51% of the samples tested positive for influenza A virus (IAV). Among the IAV-positive patients, 65% were emitters (had at least one positive air sample), reflecting a higher risk of nosocomial transmission compared with non-emitters. The majority (61.5%) of the IAV-positive air samples were collected 0.3 m from a patient's head, while the remaining IAV-positive air samples were collected 2.2 m from a patient's head. The positivity rate of IAV in air samples was influenced by distance from the patient's head and day of sample collection after hospital admission. Only three patients with RSV infection were recruited and none of them were emitters. Conclusion: Influenza virus can be aerosolized beyond 1 m in patient rooms, which is the distance considered to be safe by infection control practices. Further investigations are needed to determine the extent of infectivity of aerosolized virus particles. © 2020 The Healthcare Infection Society
dc.identifier.doihttps://doi.org/10.1016/j.jhin.2020.10.020
dc.identifier.eid2-s2.0-85099323995
dc.identifier.pmid33152397
dc.identifier.urihttp://hdl.handle.net/10938/26980
dc.language.isoen
dc.publisherW.B. Saunders Ltd
dc.relation.ispartofJournal of Hospital Infection
dc.sourceScopus
dc.subjectHospital environment
dc.subjectIndoor air quality
dc.subjectInfluenza virus
dc.subjectReal-time pcr (rt-pcr)
dc.subjectRespiratory syncytial virus
dc.subjectAdolescent
dc.subjectAdult
dc.subjectAged
dc.subjectAir microbiology
dc.subjectChild
dc.subjectChild, preschool
dc.subjectCross infection
dc.subjectFemale
dc.subjectHumans
dc.subjectInfant
dc.subjectInfant, newborn
dc.subjectInfluenza a virus
dc.subjectInfluenza, human
dc.subjectMale
dc.subjectMiddle aged
dc.subjectPatients' rooms
dc.subjectRespiratory syncytial virus infections
dc.subjectRespiratory syncytial virus, human
dc.subjectYoung adult
dc.subjectAerosol
dc.subjectAir sampling
dc.subjectArticle
dc.subjectHospital
dc.subjectHospital infection
dc.subjectHuman respiratory syncytial virus
dc.subjectInfection risk
dc.subjectReal time polymerase chain reaction
dc.subjectVirus detection
dc.subjectVirus particle
dc.subjectVirus transmission
dc.subjectVirus virulence
dc.subjectHealth care facility
dc.subjectHuman
dc.subjectInfluenza
dc.subjectIsolation and purification
dc.subjectMicrobiology
dc.subjectNewborn
dc.subjectPreschool child
dc.subjectRespiratory syncytial virus infection
dc.titleDetection of influenza virus in air samples of patient rooms
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2021-6278.pdf
Size:
633.98 KB
Format:
Adobe Portable Document Format