Triaxial response of clays reinforced with granular columns

dc.contributor.authorNajjar, Shadi S.
dc.contributor.authorSkeini, Hassan
dc.contributor.departmentDepartment of Civil and Environmental Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:26:52Z
dc.date.available2025-01-24T11:26:52Z
dc.date.issued2015
dc.description.abstractThe response of soft clays that are reinforced with granular columns is expected to be affected by the rate of loading and drainage conditions. The objective of this paper is to bracket the range of loading conditions in the field by analysing the results from 114 drained and undrained triaxial tests that were compiled in a state-of-the-knowledge database. For a given reinforcement condition, the percentage improvement in load-carrying capacity was found to be higher for undrained conditions than for drained conditions. The variation in the magnitude of the percentage improvement in strength with area replacement ratio indicated that, for drained conditions, there could be an upper bound area replacement ratio beyond which the benefits of increasing the area ratio become economically unjustifiable. The database was also utilised to test the validity of the concept of the critical column length. For both drained and undrained tests, results showed clear evidence that the rate of the percentage improvement in strength decreases significantly as the ratio of the column height to diameter increases beyond values of 5.0-6.0 for undrained tests and 7.0-10.0 for drained tests. © ICE Publishing, all rights reserved.
dc.identifier.doihttps://doi.org/10.1680/grim.13.00049
dc.identifier.eid2-s2.0-84989887103
dc.identifier.urihttp://hdl.handle.net/10938/26699
dc.language.isoen
dc.publisherThomas Telford Services Ltd
dc.relation.ispartofProceedings of the Institution of Civil Engineers: Ground Improvement
dc.sourceScopus
dc.subjectColumns/foundations/geotechnical engineering
dc.subjectReinforcement
dc.subjectTesting
dc.subjectColumns (structural)
dc.subjectFoundations
dc.subjectGeotechnical engineering
dc.subjectDrainage condition
dc.subjectGranular columns
dc.subjectKnowledge database
dc.subjectLoading condition
dc.subjectReplacement ratio
dc.subjectUndrained conditions
dc.subjectUndrained tests
dc.subjectUndrained triaxial test
dc.subjectColumn
dc.subjectGranular medium
dc.subjectLoading
dc.subjectShear strength
dc.subjectSoft clay
dc.subjectTriaxial test
dc.subjectUndrained test
dc.subjectDrained test
dc.subjectFoundation
dc.subjectDrainage
dc.titleTriaxial response of clays reinforced with granular columns
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2015-9818.pdf
Size:
258.28 KB
Format:
Adobe Portable Document Format