Demarcation Line Depth in Epithelium-Off Corneal Cross-Linking Performed at the Slit Lamp

dc.contributor.authorHafezi, Farhad
dc.contributor.authorLu, Nanji
dc.contributor.authorAssaf, Jad F.
dc.contributor.authorHafezi, Nikki L.
dc.contributor.authorKoppen, Carina
dc.contributor.authorVinciguerra, Riccardo
dc.contributor.authorVinciguerra, Paolo
dc.contributor.authorHillen, Mark J.P.
dc.contributor.authorAwwad, Shady Tanus
dc.contributor.departmentOphthalmology
dc.contributor.facultyFaculty of Medicine (FM)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T12:08:53Z
dc.date.available2025-01-24T12:08:53Z
dc.date.issued2022
dc.description.abstractWe aimed to evaluate the depth of the demarcation line following accelerated epithelium-off corneal cross-linking (A-CXL) performed at the slit lamp with the patient sitting in an upright position. Twenty-three eyes from twenty patients, undergoing epi-off A-CXL (9 mW/cm2 for 10 min) using a CXL device at the slit lamp in the upright position. Demarcation line depth was assessed at 1 month after the procedure using anterior segment optical coherence tomography (AS-OCT) and specialized software. Surgery was uneventful in all cases. The average postoperative demarcation line depth achieved was 189.4 µm (standard deviation: 58.67 µm). The demarcation line depth achieved with patients sitting upright, receiving CXL at the slit lamp, is similar to published data on CXL performed in the supine position, suggesting that demarcation line depth is not dependent on patient orientation during CXL. © 2022 by the authors.
dc.identifier.doihttps://doi.org/10.3390/jcm11195873
dc.identifier.eid2-s2.0-85139768325
dc.identifier.urihttp://hdl.handle.net/10938/31941
dc.language.isoen
dc.publisherMDPI
dc.relation.ispartofJournal of Clinical Medicine
dc.sourceScopus
dc.subjectCornea
dc.subjectCorneal cross-linking
dc.subjectCxl
dc.subjectEctasia
dc.subjectKeratoconus
dc.subjectSlit lamp
dc.subjectAlcohol
dc.subjectBalanced salt solution
dc.subjectDexamethasone plus tobramycin
dc.subjectKetorolac trometamol
dc.subjectOctenidine
dc.subjectOctenidine plus phenoxyethanol
dc.subjectOxybuprocaine
dc.subjectRibo ker
dc.subjectRiboflavin
dc.subjectTetracaine
dc.subjectAdolescent
dc.subjectAdult
dc.subjectAnterior eye segment
dc.subjectArticle
dc.subjectClinical article
dc.subjectControlled study
dc.subjectCornea epithelium
dc.subjectCorneal collagen crosslinking
dc.subjectCorneal pachymetry
dc.subjectFemale
dc.subjectHuman
dc.subjectMale
dc.subjectMeasurement accuracy
dc.subjectOptical coherence tomography
dc.subjectPatient positioning
dc.subjectPostoperative period
dc.subjectRetrospective study
dc.subjectSitting
dc.subjectSlit lamp microscopy
dc.subjectSupine position
dc.subjectUltraviolet a radiation
dc.titleDemarcation Line Depth in Epithelium-Off Corneal Cross-Linking Performed at the Slit Lamp
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2022-1487.pdf
Size:
626.63 KB
Format:
Adobe Portable Document Format

Collections