Intracortical stiffness of mid-diaphysis femur bovine bone: lacunar–canalicular based homogenization numerical solutions and microhardness measurements

dc.contributor.authorHage, Ilige S.
dc.contributor.authorHamade, Ramsey F.
dc.contributor.departmentDepartment of Mechanical Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:32:13Z
dc.date.available2025-01-24T11:32:13Z
dc.date.issued2017
dc.description.abstractAbstract: Microscale lacunar–canalicular (L-C) porosity is a major contributor to intracortical bone stiffness variability. In this work, such variability is investigated experimentally using micro hardness indentation tests and numerically using a homogenization scheme. Cross sectional rings of cortical bones are cut from the middle tubular part of bovine femur long bone at mid-diaphysis. A series of light microscopy images are taken along a line emanating from the cross-section center starting from the ring’s interior (endosteum) ring surface toward the ring’s exterior (periosteum) ring surface. For each image in the line, computer vision analysis of porosity is conducted employing an image segmentation methodology based on pulse coupled neural networks (PCNN) recently developed by the authors. Determined are size and shape of each of the lacunar–canalicular (L-C) cortical micro constituents: lacunae, canaliculi, and Haversian canals. Consequently, it was possible to segment and quantify the geometrical attributes of all individual segmented pores leading to accurate determination of derived geometrical measures such as L-C cortical pores’ total porosity (pore volume fraction), (elliptical) aspect ratio, orientation, location, and number of pores in secondary and primary osteons. Porosity was found to be unevenly (but linearly) distributed along the interior and exterior regions of the intracortical bone. The segmented L-C porosity data is passed to a numerical microscale-based homogenization scheme, also recently developed by the authors, that analyses a composite made up of lamella matrix punctuated by multi-inclusions and returns corresponding values for longitudinal and transverse Young's modulus (matrix stiffness) for these micro-sized spatial locations. Hence, intracortical stiffness variability is numerically quantified using a combination of computer vision program and numerical homogenization code. These numerically found stiffness values of the homogenization solution are corroborated experimentally using microhardness indentation measurements taken at the same points that the digital images were taken along a radial distance emanating from the interior (endosteum) surface toward the bone’s exterior (periosteum) surface. Good agreement was found between numerically calculated and indentation measured stiffness of Intracortical lamellae. Both indentation measurements and numerical solutions of matrix stiffness showed increasing linear trend of compressive longitudinal modulus (E11) values vs. radial position for both interior and exterior regions. In the interior (exterior) region of cortical bone, stiffness modulus values were found to range from 18.5 to 23.4 GPa (23 to 26.0 GPa) with the aggregate stiffness of the cortical lamella in the exterior region being 12% stiffer than that in the interior region. In order to further validate these findings, experimental and FEM simulation of a mid-diaphysis bone ring under compression is employed. The FEM numerical deflections employed nine concentric regions across the thickness with graded stiffness values based on the digital segmentation and homogenization scheme. Bone ring deflections are found to agree well with measured deformations of the compression bone ring. Graphical Abstract: [InlineMediaObject not available: see fulltext.]. © 2017, Springer Science+Business Media, LLC.
dc.identifier.doihttps://doi.org/10.1007/s10856-017-5924-5
dc.identifier.eid2-s2.0-85026787793
dc.identifier.pmid28762142
dc.identifier.urihttp://hdl.handle.net/10938/27734
dc.language.isoen
dc.publisherSpringer New York LLC
dc.relation.ispartofJournal of Materials Science: Materials in Medicine
dc.sourceScopus
dc.subjectAnimals
dc.subjectBiomechanical phenomena
dc.subjectBone density
dc.subjectCattle
dc.subjectCortical bone
dc.subjectDiaphyses
dc.subjectElasticity
dc.subjectFemur
dc.subjectHaversian system
dc.subjectPorosity
dc.subjectAspect ratio
dc.subjectComputer vision
dc.subjectElastic moduli
dc.subjectImage processing
dc.subjectImage segmentation
dc.subjectMammals
dc.subjectMatrix algebra
dc.subjectMicrohardness
dc.subjectNeural networks
dc.subjectStiffness
dc.subjectStiffness matrix
dc.subjectHomogenization scheme
dc.subjectIndentation measurements
dc.subjectMicrohardness indentation
dc.subjectMicrohardness measurement
dc.subjectNumerical homogenization
dc.subjectPore volume fractions
dc.subjectPulse coupled neural network
dc.subjectTransverse young's modulus
dc.subjectArticle
dc.subjectBone tissue
dc.subjectBovine
dc.subjectCanaliculi canal
dc.subjectCross-sectional study
dc.subjectDiaphysis
dc.subjectEndosteum
dc.subjectHardness
dc.subjectHaversian canal
dc.subjectLacunae canal
dc.subjectLacunar canalicular porosity
dc.subjectMicroscopy
dc.subjectNonhuman
dc.subjectPeriosteum
dc.subjectPriority journal
dc.subjectYoung modulus
dc.subjectAnimal
dc.subjectBiomechanics
dc.subjectPhysiology
dc.subjectBone
dc.titleIntracortical stiffness of mid-diaphysis femur bovine bone: lacunar–canalicular based homogenization numerical solutions and microhardness measurements