BrightOcular® Cosmetic Iris Implant: A Spectrum from Tolerability to Severe Morbidity

dc.contributor.authorKoaik, Mona K.
dc.contributor.authorMansour, Ahmad Mohammed Farid Mahmoud
dc.contributor.authorSaad, Alain
dc.contributor.authorFarah, Samir G.
dc.contributor.departmentOphthalmology
dc.contributor.facultyFaculty of Medicine (FM)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T12:08:36Z
dc.date.available2025-01-24T12:08:36Z
dc.date.issued2018
dc.description.abstractPurpose: The BrightOcular® implants are the newest model of cosmetic iris devices that are currently advertised as safe. The previous generation known as NewColorIris® have had severe ocular side effects and were subsequently withdrawn from the market. There is little literature on the safety profile of BrightOcular® implants. Case Report: Herein we describe two cases with varying degrees of ocular tolerability. The first case had a normal ocular exam 1 year after implantation, whereas the second case had unilateral severe corneal edema requiring explantation of the iris device and Descemet membrane endothelial keratoplasty 9 months after bilateral implantation. Conclusions: These two cases attest to the unpredictability of the results of these cosmetic surgeries. Patients should be counseled about the vision-threatening complications of iris implants. © 2018 The Author(s).
dc.identifier.doihttps://doi.org/10.1159/000492745
dc.identifier.eid2-s2.0-85052949133
dc.identifier.urihttp://hdl.handle.net/10938/31857
dc.language.isoen
dc.publisherS. Karger AG
dc.relation.ispartofCase Reports in Ophthalmology
dc.sourceScopus
dc.subjectBrightocular® iris implant
dc.subjectCosmetic iris implants
dc.subjectSafety
dc.subjectTolerability
dc.subjectDexamethasone
dc.subjectTobramycin
dc.subjectAdult
dc.subjectAnterior eye chamber depth
dc.subjectAnterior eye segment
dc.subjectArticle
dc.subjectBest corrected visual acuity
dc.subjectBlurred vision
dc.subjectCase report
dc.subjectCaucasian
dc.subjectCell density
dc.subjectCentral corneal thickness
dc.subjectClinical article
dc.subjectCornea edema
dc.subjectCorneal pachymetry
dc.subjectDescemet membrane endothelial keratoplasty
dc.subjectDisease duration
dc.subjectDisease severity
dc.subjectEndothelium cell
dc.subjectEsthetic surgery
dc.subjectEye refraction
dc.subjectFemale
dc.subjectFollow up
dc.subjectGonioscopy
dc.subjectHuman
dc.subjectIndia
dc.subjectIntraocular pressure
dc.subjectKeratomileusis
dc.subjectMorbidity
dc.subjectMyopia
dc.subjectOpen angle glaucoma
dc.subjectOphthalmoscopy
dc.subjectOptical coherence tomography
dc.subjectPatient safety
dc.subjectPriority journal
dc.subjectRetinal nerve fiber layer thickness
dc.subjectSlit lamp microscopy
dc.subjectSurgical technique
dc.subjectVisual acuity
dc.subjectVisual field
dc.subjectVitreous floaters
dc.titleBrightOcular® Cosmetic Iris Implant: A Spectrum from Tolerability to Severe Morbidity