Design and development of microscale thickness shear mode (TSM) resonators for sensing neuronal adhesion

dc.contributor.authorKhraiche, Massoud Louis
dc.contributor.authorRogul, Jonathan
dc.contributor.authorMuthuswamy, Jit
dc.contributor.departmentBiomedical Engineering Program
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:25:57Z
dc.date.available2025-01-24T11:25:57Z
dc.date.issued2019
dc.description.abstractThe overall goal of this study is to develop thickness shear mode (TSM) resonators for the real-time, label-free, non-destructive sensing of biological adhesion events in small populations (hundreds) of neurons, in a cell culture medium and subsequently in vivo in the future. Such measurements will enable the discovery of the role of biomechanical events in neuronal function and dysfunction. Conventional TSM resonators have been used for chemical sensing and biosensing applications in media, with hundreds of thousands of cells in culture. However, the sensitivity and spatial resolution of conventional TSM devices need to be further enhanced for sensing smaller cell populations or molecules of interest. In this report, we focus on key challenges such as eliminating inharmonics in solution and maximizing Q-factor while simultaneously miniaturizing the active sensing (electrode) area to make them suitable for small populations of cells. We used theoretical expressions for sensitivity and electrode area of TSM sensors operating in liquid. As a validation of the above design effort, we fabricated prototype TSM sensors with resonant frequencies of 42, 47, 75, and 90 MHz and characterized their performance in liquid using electrode diameters of 150, 200, 400, 800, and 1,200 μm and electrode thicknesses of 33 and 230 nm. We validated a candidate TSM resonator with the highest sensitivity and Q-factor for real-time monitoring of the adhesion of cortical neurons. We reduced the size of the sensing area to 150-400 μm for TSM devices, improving the spatial resolution by monitoring few 100-1,000s of neurons. Finally, we modified the electrode surface with single-walled carbon nanotubes (SWCNT) to further enhance adhesion and sensitivity of the TSM sensor to adhering neurons (Marx, 2003). , Copyright © 2019 Khraiche, Rogul and Muthuswamy.
dc.identifier.doihttps://doi.org/10.3389/fnins.2019.00518
dc.identifier.eid2-s2.0-85068578908
dc.identifier.urihttp://hdl.handle.net/10938/26448
dc.language.isoen
dc.publisherFrontiers Media S.A.
dc.relation.ispartofFrontiers in Neuroscience
dc.sourceScopus
dc.subjectAcoustic sensors
dc.subjectAdhesion
dc.subjectCarbon nanotubes
dc.subjectMicroelectrode
dc.subjectNeural interfaces
dc.subjectNeuron
dc.subjectQuartz crystal microbalance (qcm)
dc.subjectUltrasound
dc.subjectCarbon nanotube
dc.subjectAnalytical parameters
dc.subjectAnimal cell
dc.subjectArticle
dc.subjectBiomechanics
dc.subjectBrain nerve cell
dc.subjectCell adhesion
dc.subjectCell culture
dc.subjectCell function
dc.subjectCell population
dc.subjectControlled study
dc.subjectEmbryo
dc.subjectEquipment design
dc.subjectLiquid
dc.subjectMeasurement
dc.subjectMicroscale thickness shear mode resonator
dc.subjectMonitoring
dc.subjectNonhuman
dc.subjectPerformance
dc.subjectQuality factor
dc.subjectRat
dc.subjectScanning electron microscopy
dc.subjectSprague dawley rat
dc.subjectSurface property
dc.subjectThickness
dc.subjectValidation study
dc.subjectViscoelasticity
dc.titleDesign and development of microscale thickness shear mode (TSM) resonators for sensing neuronal adhesion
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2019-7792.pdf
Size:
2.74 MB
Format:
Adobe Portable Document Format