Flexural capacity of fiber-reinforced polymer strengthened unbonded post-tensioned members

dc.contributor.authorEl Meski, Fatima
dc.contributor.authorHarajlí, Mohamed H.
dc.contributor.departmentDepartment of Civil and Environmental Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:26:48Z
dc.date.available2025-01-24T11:26:48Z
dc.date.issued2014
dc.description.abstractExperimental and analytical investigations were carried out for evaluating the nominal moment capacity of unbonded posttensioned members when strengthened using external fiberreinforced polymer (FRP) composites. In the experimental part of the study, 36 simply supported specimens were tested to failure. The main test parameters included area of internal tension reinforcement, area of external FRP reinforcement, span-depth ratio of the member, profile of the prestressing tendons, and type of concrete structural system. In the analytical part of the study, a designoriented procedure for evaluating the nominal moment capacity of FRP-strengthened post-tensioned members with internal or external unbonded tendon systems is developed. The procedure is consistent with the approach proposed in ACI Committee 440 report for reinforced concrete or bonded prestressed concrete members, and is applicable for both simply supported and continuous members. The accuracy of the design approach was verified by comparing it with the test results of the experimental part of this investigation. Copyright © 2014, American Concrete Institute.
dc.identifier.doihttps://doi.org/10.14359/51686565
dc.identifier.eid2-s2.0-84907422020
dc.identifier.urihttp://hdl.handle.net/10938/26663
dc.language.isoen
dc.publisherAmerican Concrete Institute
dc.relation.ispartofACI Structural Journal
dc.sourceScopus
dc.subjectFiber-reinforced polymer
dc.subjectFlexure
dc.subjectPost-tensioning
dc.subjectPrestressing
dc.subjectStrengthening
dc.subjectUnbonded tendons
dc.subjectFiber reinforced plastics
dc.subjectPolymers
dc.subjectReinforced concrete
dc.subjectReinforcement
dc.subjectStrengthening (metal)
dc.subjectWire
dc.subjectAnalytical investigations
dc.subjectDesign approaches
dc.subjectFiber reinforced polymers
dc.subjectPosttensioning
dc.subjectPrestressing tendon
dc.subjectStructural systems
dc.subjectPrestressed concrete
dc.titleFlexural capacity of fiber-reinforced polymer strengthened unbonded post-tensioned members
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2014-5364.pdf
Size:
661.31 KB
Format:
Adobe Portable Document Format