Effectiveness of contaminant confinement in office spaces equipped with ceiling personalized ventilation system

dc.contributor.authorAlotaibi, Sorour A.
dc.contributor.authorChakroun, Walid M.
dc.contributor.authorHabchi, Carine Hanna
dc.contributor.authorGhali, Kamel Abou
dc.contributor.authorGhaddar, Nesreen K.
dc.contributor.departmentDepartment of Mechanical Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:32:19Z
dc.date.available2025-01-24T11:32:19Z
dc.date.issued2018
dc.description.abstractCreating a micro-environment around infected occupants constitutes an effective strategy in reducing contaminants spread insuring a relatively clean macroclimate decreasing the risk of infection for occupants circulating in an office space. In this work, the ability of ceiling personalized ventilation (CPV) system assisted by desk fans (DF) or chair fans (CF) was studied with respect to confining contaminants spread in typical office space while considering possible occupant shift. A 3D computational fluid dynamics (CFD) model was developed to simulate particle spread. The developed model was validated experimentally with respect to concentration values using a thermal manikin in a climatic chamber with controlled particle generation. A parametric study was followed to determine the effect of the occupant shift from CPV design position, the CPV+DF or CF configuration, and the canopy angle on confinement performance for minimal particle spread in the space. The CPV jet and diffusers’ flow canopy favored particle deposition within the microclimate region leading to their removal from indoor air. For no occupant shift, assisting the CPV jet by DF or CF was very efficient in particle confinement. However, in the cases of critical backward occupant shift, flow asymmetry was formed around the occupant leading to particle spread and leading to asymmetry attenuation when operated with CF. The highest particle confinement was obtained for a canopy angle of 45° for the case of CPV assisted by CF due to forming a recirculation zone between the CPV and jet diffusers; hence trapping particles and reducing their spread to the macroclimate. It was found that a total supply flow rate of 60 L/s for MV is required compared to 43.5 L/s for the optimal CPV design, for equivalent average particle concentration within the macroclimate zone at the critical generation plane, leading to 62% reduction in power consumption of the supply fan. © 2018, Tsinghua University Press and Springer-Verlag GmbH Germany, part of Springer Nature.
dc.identifier.doihttps://doi.org/10.1007/s12273-018-0437-9
dc.identifier.eid2-s2.0-85048658587
dc.identifier.urihttp://hdl.handle.net/10938/27766
dc.language.isoen
dc.publisherTsinghua University Press
dc.relation.ispartofBuilding Simulation
dc.sourceScopus
dc.subjectCeiling personalized ventilation
dc.subjectConcentration asymmetry
dc.subjectContaminant confinement
dc.subjectEnergy savings
dc.subjectMacroclimate zone
dc.subjectCeilings
dc.subjectComputational fluid dynamics
dc.subjectContamination
dc.subjectEnergy conservation
dc.subjectFighter aircraft
dc.subjectImpurities
dc.subjectOffice buildings
dc.subjectComputational fluid dynamics modeling
dc.subjectConcentration values
dc.subjectParticle concentrations
dc.subjectParticle confinement
dc.subjectParticle depositions
dc.subjectParticle generation
dc.subjectPersonalized ventilation
dc.subjectPersonalized ventilation systems
dc.subjectVentilation
dc.titleEffectiveness of contaminant confinement in office spaces equipped with ceiling personalized ventilation system
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2018-8031.pdf
Size:
2.39 MB
Format:
Adobe Portable Document Format