Bedside echocardiography and passive leg raise as a measure of volume responsiveness in the emergency department

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

John Wiley and Sons Ltd.

Abstract

Objectives—The aim of this study was to investigate the value of bedside echocardiography with a passive leg raise as a noninvasive marker of volume responsiveness. Methods—This work was a prospective observational study of patients with end-stage renal disease presenting to the emergency department. The left ventricular outflow tract (LVOT) velocity time integral (VTI) was obtained. Measurements before and after dialysis as well as before and after the passive leg raise were recorded. Results—Fifty-four patients were enrolled, in whom the mean volume of fluid removed ± SD was 3.89 ± 0.91 L. In the predialysis cohort, the mean LVOT VTI was 28.05 cm (95% confidence interval [CI], 26.55–29.55 cm). After the passive leg raise, the mean VTI was 28.52 cm (95% CI, 26.98–30.07 cm). In the postdialysis cohort, the mean VTI was 30.31 cm (95% CI, 28.92–31.69 cm), and it increased to 34.91 cm (95% CI, 33.11–36.72 cm) after the passive leg raise. The Δ VTI values were 1.83% (95% CI, 0.12%–3.55%) in the predialysis group and 15.05% (95% CI, 12.76%–17.34%) in the postdialysis cohort. When stratified by fluid removal, the mean Δ VTI values after hemodialysis were 12.64% (95% CI, 9.79%–15.49%) and 16.84% (95% CI, 13.47%–20.22%) for patients who had less than 4 L and 4 L or greater removed, respectively. In patients without congestive heart failure, the Δ VTI was 15.28% (95% CI, 12.25%–18.32%), whereas for those with congestive heart failure, the mean change was 14.63% (95% CI, 10.91%–18.35%). Conclusions—The LVOT VTI in conjunction with a passive leg raise seems to correlate with the volume status and volume responsiveness. © 2018 by the American Institute of Ultrasound in Medicine.

Description

Keywords

Echocardiography, Emergency medicine, Fluid responsiveness, Hemodialysis, Left ventricular outflow tract, Passive leg raise, Velocity time integral, Emergency service, hospital, Female, Heart failure, Heart ventricles, Humans, Kidney failure, chronic, Leg, Male, Middle aged, Patient positioning, Point-of-care testing, Prospective studies, Renal dialysis, Stroke volume, Cardiology, Dialysis, Emergency rooms, Hemodialyzers, Outflow tracts, Time integrals, Chronic kidney failure, Complication, Heart stroke volume, Heart ventricle, Hospital emergency service, Human, Pathophysiology, Physiology, Point of care testing, Procedures, Prospective study

Citation

Endorsement

Review

Supplemented By

Referenced By