Impact of the reference point for epithelial thickness measurements

dc.contributor.authorArba Mosquera, Samuel
dc.contributor.authorAwwad, Shady Tanus
dc.contributor.departmentOphthalmology
dc.contributor.facultyFaculty of Medicine (FM)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T12:08:42Z
dc.date.available2025-01-24T12:08:42Z
dc.date.issued2020
dc.description.abstractPURPOSE: To analyze the implications of different reference points on the read-out of epithelial thickness mapping. METHODS: A simulation for changing the reference point from normal-to-the-surface tangent to parallel vertical sections quantifying its effect on the read-out of epithelial thickness mapping has been developed. The simulation includes a simple modeling of corneal epithelial profiles and allows the analytical quantification of the differences in the read-out from normal-to-the-surface tangent to parallel vertical sections epithelial thickness mapping. RESULTS: The difference in the read-out between parallel vertical sections and normal-to-the-surface tangent epithelial thickness mapping increases for steeper corneas, but it is not largely affected by asphericity. The difference increases for thicker epithelia. CONCLUSIONS: The reference point for determining the readout of epithelial thickness mapping should be taken into account when interpreting output. Using conventional epithelial thickness map readings (normal-to-the surface tangent) in transepithelial ablations (representing close to parallel vertical sections) may result in induced refractive errors that can be quantified using simple theoretical simulations, because the center-to-periphery progression of the corneal epithelial profile deviates from the progression of the ablated one. Adjustments for the epithelial thickness read-out or, alternatively, for the target sphere can be easily derived. Copyright © SLACK Incorporated
dc.identifier.doihttps://doi.org/10.3928/1081597X-20200127-01
dc.identifier.eid2-s2.0-85081900759
dc.identifier.pmid32159825
dc.identifier.urihttp://hdl.handle.net/10938/31892
dc.language.isoen
dc.publisherSlack Incorporated
dc.relation.ispartofJournal of Refractive Surgery
dc.sourceScopus
dc.subjectCorneal pachymetry
dc.subjectEpithelium, corneal
dc.subjectFemale
dc.subjectHumans
dc.subjectMale
dc.subjectModels, theoretical
dc.subjectOrgan size
dc.subjectReference values
dc.subjectArticle
dc.subjectCornea epithelium
dc.subjectCornea thickness
dc.subjectGeometry
dc.subjectHuman
dc.subjectKeratoconus
dc.subjectKeratomileusis
dc.subjectMeasurement
dc.subjectMyopia
dc.subjectNormal to the surface tangent
dc.subjectParallel vertical section
dc.subjectPhotorefractive keratectomy
dc.subjectPriority journal
dc.subjectReference value
dc.subjectRefraction error
dc.subjectSimulation
dc.subjectAnatomy and histology
dc.subjectTheoretical model
dc.titleImpact of the reference point for epithelial thickness measurements
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2020-3383.pdf
Size:
2.24 MB
Format:
Adobe Portable Document Format

Collections