Drained triaxial response of clay reinforced with sand columns

dc.contributor.authorNajjar, Shadi S.
dc.contributor.authorSadek, Salah M.
dc.contributor.authorBou Lattouf, Hani
dc.contributor.authorMaalouf, Yara S.
dc.contributor.departmentDepartment of Civil and Environmental Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:27:51Z
dc.date.available2025-01-24T11:27:51Z
dc.date.issued2020
dc.description.abstractIn ground-improvement applications involving stone columns in soft clays, the columns act as drains that facilitate partial drainage during practical load applications. Partial drainage could improve the short-term strength of the clay/column composite. The objective of this work was to bracket the range of loading conditions by investigating the fully drained response of clay/column composites through consolidated drained triaxial tests. The area replacement ratio, the column penetration ratio and the presence of geotextile encasement were varied in the testing programme. A maximum improvement of 69% was observed in the deviatoric stress for area replacement ratios of 31·7%. A comparison between identical drained and undrained tests indicated that the deviatoric stresses were higher in drained tests with the drained response representing an upper bound for the strength of the reinforced clay specimens. When the improvements observed in triaxial tests were compared with improvements witnessed in full-scale footing tests, the triaxial test results seemed to over predict the per cent improvement observed in the field bearing capacity. © ICE Publishing: All rights reserved.
dc.identifier.doihttps://doi.org/10.1680/jgrim.18.00007
dc.identifier.eid2-s2.0-85089485629
dc.identifier.urihttp://hdl.handle.net/10938/26960
dc.language.isoen
dc.publisherICE Publishing
dc.relation.ispartofProceedings of the Institution of Civil Engineers: Ground Improvement
dc.sourceScopus
dc.subjectColumns
dc.subjectGeotechnical engineering
dc.subjectModels (physical)
dc.subjectReinforcement
dc.subjectStresses
dc.subjectTesting
dc.subjectConsolidated drained
dc.subjectDeviatoric stress
dc.subjectGround improvement
dc.subjectLoad application
dc.subjectLoading condition
dc.subjectPartial drainage
dc.subjectPenetration ratio
dc.subjectReplacement ratio
dc.subjectBearing capacity
dc.subjectComposite
dc.subjectConsolidation
dc.subjectLoading
dc.subjectSand
dc.subjectSoft clay
dc.subjectStress field
dc.subjectTriaxial test
dc.subjectDrainage
dc.titleDrained triaxial response of clay reinforced with sand columns
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2020-3113.pdf
Size:
2.12 MB
Format:
Adobe Portable Document Format