Optimized performance of displacement ventilation aided with chair fans for comfort and indoor air quality

dc.contributor.authorAbou-Hweij, Walid
dc.contributor.authorGhaddar, Nesreen K.
dc.contributor.authorGhali, Kamel Abou
dc.contributor.authorHabchi, Carine Hanna
dc.contributor.departmentDepartment of Mechanical Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:32:05Z
dc.date.available2025-01-24T11:32:05Z
dc.date.issued2016
dc.description.abstractThis study optimizes the performance of displacement ventilation (DV) system aided with chair fans (CF) for providing acceptable thermal comfort and indoor air quality (IAQ) in office space. A 3-D computational fluid dynamics (CFD) model coupled with a bio-heat model was used to predict the airflow, temperature, and CO2 concentrations fields as well as the occupant segmental skin temperatures for local and overall thermal sensation and comfort evaluation. The CFD model results were validated experimentally in a DV conditioned space using a thermal manikin seated on a chair equipped with fans. Simulations were performed using the validated CFD model to determine the fans optimal height from the floor. For a pollution source located at 1.0 m from the floor, it is recommended to place the fans at 30.9 cm above the floor at fans total flow rate of 12 L/s while for a pollution source located at 0.3 m from the floor, the optimal height of fans is at 30.1 cm above the floor at fans total flow rate of 12 L/s. Compared to stand alone DV system, energy savings were 20.6% and 11.6% for fans’ optimal heights of the sources placed at 1.0 m and 0.3 m, respectively. © 2016 Elsevier B.V.
dc.identifier.doihttps://doi.org/10.1016/j.enbuild.2016.06.052
dc.identifier.eid2-s2.0-84976558390
dc.identifier.urihttp://hdl.handle.net/10938/27681
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEnergy and Buildings
dc.sourceScopus
dc.subjectChair fans
dc.subjectDisplacement ventilation
dc.subjectEnergy savings
dc.subjectIndoor air quality
dc.subjectThermal comfort
dc.subjectAir
dc.subjectAir quality
dc.subjectCarbon dioxide
dc.subjectComputational fluid dynamics
dc.subjectEnergy conservation
dc.subjectFloors
dc.subjectIndoor air pollution
dc.subjectOffice buildings
dc.subjectPollution
dc.subjectSensory perception
dc.subjectComfort evaluation
dc.subjectComputational fluid dynamics modeling
dc.subjectOptimized performance
dc.subjectOverall thermal sensations
dc.subjectPollution sources
dc.subjectSkin temperatures
dc.subjectVentilation
dc.titleOptimized performance of displacement ventilation aided with chair fans for comfort and indoor air quality
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2016-9312.pdf
Size:
3.35 MB
Format:
Adobe Portable Document Format