Optimizing the use of natural ventilation while reducing energy cost_case study for retrofitting an old residential apartment in a Mediterranean city

dc.contributor.authorYeretzian, Aram
dc.contributor.authorKaram, Jennifer
dc.contributor.departmentDepartment of Architecture and Design
dc.contributor.departmentDepartment of Mechanical Engineering
dc.contributor.facultyMaroun Semaan Faculty of Engineering and Architecture (MSFEA)
dc.contributor.institutionAmerican University of Beirut
dc.date.accessioned2025-01-24T11:26:09Z
dc.date.available2025-01-24T11:26:09Z
dc.date.issued2023
dc.description.abstractThis study investigates the effects of using a hybrid natural ventilation (NV) and HVAC system in old residential buildings in the Mediterranean city of Beirut. The system operates with a control strategy that maximizes the reliance on NV and reduces the energy cost when the HVAC system is needed. To maximize the performance of the proposed system, this work proposes the addition of insulation panels and the modification of the windows glazing type according to the orientation of the exposed walls. An optimization procedure is carried out to optimize the performance of the insulation layers and the glazing material for each external wall orientation and for the current Mediterranean climate. To this aim, a model to predict the hours of NV, the corresponding penetrating outdoor airflow rate as well as the energy consumption and the average indoor temperature is developed and calibrated using the EnergyPlus software. A genetic algorithm is used to optimize the life cycle cost equation. It was found that depending on the wall orientation, the optimal thermal insulation thickness varied between 20 mm and 40 mm while the glazing U-value varied between 1.7 W/m2·K and 3.2 W/m2·K. These retrofitting strategies and methods resulted in 22% energy savings and 20% more hours of NV per year with respect to the reference case when no retrofit strategies were used. © 2023 Elsevier B.V.
dc.identifier.doihttps://doi.org/10.1016/j.enbuild.2023.113371
dc.identifier.eid2-s2.0-85165361235
dc.identifier.urihttp://hdl.handle.net/10938/26502
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEnergy and Buildings
dc.sourceScopus
dc.subjectCross-ventilation
dc.subjectEnergy efficiency in ventilation
dc.subjectHybrid ventilation system
dc.subjectOptimization
dc.subjectRetrofitting of building envelope
dc.subjectAir conditioning
dc.subjectCost reduction
dc.subjectEnergy utilization
dc.subjectGenetic algorithms
dc.subjectGlazes
dc.subjectHousing
dc.subjectLife cycle
dc.subjectRetrofitting
dc.subjectThermal insulation
dc.subjectVentilation
dc.subjectWalls (structural partitions)
dc.subjectBuilding envelopes
dc.subjectCross ventilation
dc.subjectEnergy cost
dc.subjectHvac system
dc.subjectMediterranean cities
dc.subjectNatural ventilation
dc.subjectOptimisations
dc.subjectEnergy efficiency
dc.titleOptimizing the use of natural ventilation while reducing energy cost_case study for retrofitting an old residential apartment in a Mediterranean city